Find a Dealer
Default Background Desktop Default Background Mobile

Explore Our FlowGuard Plus CPVC Range

All Filters
70 Products
Apply filters
  • Pipes (4)
  • Fittings (55)
  • SCH 80 Fittings (6)
  • SCH 40 Fittings (2)
  • Solvent (3)
Ashirvad two-way Korrosafe union water connector
Union

The Ashirvad two-way Korrosafe union is a water pipe connector fitting used

Tee
Tee

The Tee is an Agri pipe fitting that connects a horizontal pipe

Ashirvad's Brass Tee MABT CPVC fitting
Brass Tee MABT

The Brass tee MABT is an advanced CPVC fitting that is used

Ashirvad's CPVC fitting
Nail Clamp

This stainless-steel nail clamp features attached stainless steel nails that provide ease

Ashirvad's CPVC Reducing FABT
CPVC Reducing FABT

The Reducing Male Adapter Brass Threaded fitting is used to connect two

Ashirvad's Brass Union FABT
Brass Union FABT

The Brass Union- Female Adaptor Brass Threaded fitting is a hybrid joint

Icon Features

Why Choose Us?

Globally Trusted CPVC Technology

Powered by Lubrizol’s NSF-certified CPVC, tested internationally and trusted for over a decade—delivering safe, reliable plumbing for millions of households across India.

Built for Harsh Indian Conditions

Handles high pressure and temperatures up to 93°C, resists corrosion, scaling and harmful substances—ensuring durability in India’s toughest climates with minimal maintenance.

Superior Water Quality & Hygiene

Provides clean, fresh water without metallic taste or odors, completely lead-free and rust-free for healthier living.

Innovation for Effortless Installation

Ashirvad’s patented self-alignment design ensures precise, hassle-free fittings, reducing installation time and errors.

Icon Resources

Technical specifications

Download

Technical specifications

Download
Icon Installation

Install with Confidence. Maintain with Ease.

Step 1

Plan Layout

Mark pipe routes to minimize bends and ensure smooth water flow.

Step 2

Apply Primer

Use purple primer to clean and prep pipe ends for strong bonding.

Step 3

Secure Joints

Apply Ashirvad CPVC solvent cement for leak-proof, durable joints.

Step 4

Inspection

Test the system for flow and pressure before finalizing the installation.

Icon Do’s and Don’ts

Do’s

Plan a Clear Route: Map out hot and cold water lines separately to avoid confusion and ensure efficient flow.

Use Proper Transition Fittings: When connecting CPVC to metal pipes, always use compatible transition fittings to prevent corrosion or leaks.

Select the Right Pressure Rating: Choose pipes and fittings that match your building’s pressure and temperature requirements.

Label Lines Clearly: Mark hot and cold lines during installation to avoid mix-ups during maintenance or repairs.

Replace Worn-Out Parts Promptly: Swap out damaged or aged components to maintain system integrity and performance.

Don’ts

Don’t Mix CPVC with Incompatible Metals: Avoid direct contact with metals like galvanized steel without proper fittings—it can lead to failure.

Don’t Skip Line Labeling: Unmarked lines can cause hot/cold water confusion and costly rework.

Don’t Ignore Subtle Leaks: Even small drips can signal bigger issues—address them early to prevent damage.

Pioneering innovations in piping solutions

Enhanced Lubrizol Resin Technology

Enhanced Lubrizol Resin Technology

Our exclusive resin blend, powered by Lubrizol, delivers superior durability and long-term performance under daily wear and tear.

Smart Joint Design

Smart Joint Design

Engineered for precision, FlowGuard® Plus fittings ensure secure connections with minimal risk of leaks—keeping your plumbing system worry-free.

Eco-Conscious Manufacturing

Eco-Conscious Manufacturing

Produced in environmentally responsible facilities, FlowGuard® Plus pipes help reduce resource waste and lower your carbon footprint.

Tested for Extreme Conditions

Tested for Extreme Conditions

Rigorously tested beyond standard industry requirements, FlowGuard® Plus stands strong against high temperatures, pressure, and aggressive water conditions.

Ready to explore Ashirvad FlowGuard Plus for your home or project?
Let’s chat.

Get in Touch

What’s Flowing: Trusted Tips &
Smart Plumbing Insights

View All

By joining forces with Aliaxis, we blend global R&D with local insights—paving the way for India’s water future.

Learn More About Aliaxis

Frequently Asked Questions

How are Ashirvad FLOWGUARD™ PLUS CPVC pipes and fittings aligned?

At Ashirvad, we have innovated extensively to enable optimum alignment of fittings with pipes during installation. Under our unique Self Alignment System, elbows and fittings in the 1/2”, 3/4”, and 1” size range feature an alignment mould mark that is to be matched with the red stripe on the pipe during the solvent cement push fitment process. This simple color-coded process ensures that the water outlet fittings are perpendicular to the wall surface in the concealed installations and hence, avoid any repair, breakage, within the plumbing system after the wall finishing has been completed. This Self Alignment System serves as a very useful and convenient reference to the plumber during installation in unplastered walls while also saving on extra time and cost in repairing future non-aligned joints. We’re proud to say that our Self-Alignment system is an industry-first innovation by Ashirvad pipes which is not just design registered to our name but is also recognized around the world.

At Ashirvad, we use a unique UV protected CPVC compound supplied by Lubrizol to manufacture pipes and fitting. After being in use for over 50 years, the FLOWGUARD™ PLUS CPVC pipes have displayed no deterioration in pressure withstanding capacity after decades of exposure to sunlight even after several years of installation. However, for extra protection for pipes that are directly under harsh sunlight, we recommend covering all pipes and fittings installed on the roof to prevent any kind of mechanical damage to the system.

We have devised a unique system for repairing CPVC pipe without cutting out the damaged portion for repair. Here’s how you can repair punctured and damaged pipe caused by drilling/chiseling :

–  Start by removing the cement plaster and using the pipe repair piece supplied by the company.

–  Thoroughly clean the damaged area of the pipe and make it dry.

–  Apply solvent cement on the surface of the pipe at the damaged portion around the entire circumference.

– Apply solvent cement on the inner surface of the pipe and weld it together on the damaged area.

–  Tie a small piece of string/binding wire around the repair piece and pipe till the solvent sets in and solidifies.

–  Conduct a pressure test before replastering.

The thermal conductivity of FLOWGUARD™ PLUS CPVC pipes and fittings is 0.14 W/MK whereas that of copper is 400 W/MK. Since CPVC is a bad conductor of heat, light insulation is recommended only for installations where there is a continuous flow of hot water e.g. solar/centralized heaters. For bathrooms with independent heaters within 3 meters, insulation may not be necessary. Please ensure that the insulation material or glue used to hold the insulation material is free of any phthalate plasticizer which is not compatible with CPVC and may cause failure within the plumbing system in the long run.